  • DMF-Z Right Angle Electromagnetic Pulse Valve
    product name:

    DMF-Z Right Angle Electromagnetic Pulse Valve

    product description:

    The DMF-Z electromagnetic pulse valve is a right-angle valve with an included angle of 90 degrees between the inlet and outlet. It is suitable for the installation and connection of the air cylinder and the dust blowing nozzle.

    details

    The use of DMF-Z right-angle electromagnetic pulse valve

    DMF-Z right-angle electromagnetic pulse valve is the compressed air "switch" of the pulse bag dust removal system. Controlled by the output signal of the pulse spray controller, the filter bag is sprayed and cleaned row by row (room) to keep the resistance of the dust collector within the set range to ensure the processing capacity and dust collection efficiency of the dust collector.

    The DMF-Z electromagnetic pulse valve is a right-angle valve with an included angle of 90 degrees between the inlet and outlet. It is suitable for the installation and connection of the air cylinder and the dust removal blowing pipe.

    Technical parameters of DMF-Z right-angle electromagnetic pulse valve

    Working pressure: 0.3-0.6MPa

    Working medium: clean air

    Voltage: DC24V / AC220V

    Current: 800mA / 60mA

    Use environment: temperature ℃ -65 ℃ relative humidity of air does not exceed 85%

    Service life: 1 million times or 2-3 years

    DMF-Z right angle electromagnetic pulse valve characteristics

    Multi-purpose voltage: 24V ~ 240V AC / DC

    Timing time: 0.5-10s on, 0.5-45min off

    Simple installation, fully automatic, maintenance-free

    Working principle of DMF-Z right-angle electromagnetic pulse valve

    The diaphragm divides the electromagnetic pulse valve into two front and rear air chambers. When the compressed air passes through the orifice and enters the acquired chamber, the pressure of the rear chamber closes the diaphragm to the output port of the valve, and the electromagnetic pulse valve is in the "closed" position. "status. The electrical signal of the pulse injection controller disappeared, the armature of the electromagnetic pulse valve was reset, the vent hole of the rear air chamber was closed, and the pressure of the rear air chamber was raised to make the film close to the valve outlet, and the electromagnetic pulse valve was in the "closed" state.